Reverberation Chamber
ETS-Lindgren reverberation chambers provide a diffuse-field environment that enables sound absorption tests, sound power tests, and transmission loss studies to be performed.
Faraday provide consultancy services ranging from design input at the schematic design stage all the way through to EMF calculations on electrical systems which have already been designed.
At schematic design stage Faraday provide advice on electrical cable reticulation and substation design to minimise EMF levels. Faraday can also assist with correct scoping for Electrical specifications, ensuring costs are accurately captured when jobs go out to tender.
Where the power system for a building has already been designed, Faraday can calculate EMF levels throughout the building and advise where EMF shielding needs to be installed. This allows substations, switch rooms and cable trays to be shielded at the appropriate stage during construction of the building.
All calculations are presented in a full report which provides expected EMF levels in key locations and recommendations which clearly state where shielding is required and the attenuation level required in each location.
ETS-Lindgren reverberation chambers provide a diffuse-field environment that enables sound absorption tests, sound power tests, and transmission loss studies to be performed.
Nulla amet – aenean sollicitudin, lorem quis bibendum auctor, nisi elit consequat ipsum nec sagittis.
Faraday can also perform testing of ambient EMF levels in existing buildings with live electrical systems to assess the impact of interference on proposed installation of sensitive equipment.
An MRI scanner is essentially a large, permanently active electro-magnet. They are used to diagnose and monitor patients with diseases or injuries. The magnetic fields proceed by MRI scanners are significant and are generally required to be contained within the bounds of a shielded room.
MRI scanners are highly susceptible to interference from external radio frequency signals. Interference can cause image quality problems for MRI procedures, reducing or completely spoiling the quality of the scan.
Proper evaluation of existing and new planned construction is invaluable in dealing with high levels of EMI and meeting regional and national requirements for prolonged exposure to EMI.
We have a dedicated team of sales, project management, drafting, technical and installation specialists who ensure an end to end solution which is unrivalled in the Australian market.
Our anechoic chambers are designed to completely absorb reflections of sound or electromagnetic waves. They are also isolated from waves entering from their surroundings.